Cyclic Saturated Hydrocarbons


Cyclohexane

Cartridge Type Concentration Relative Humidity Minutes to
300 ppm
(OSHA PEL)
Minutes to
200 ppm
Minutes to
50 ppm
GMA Adv. 200 200 ppm 50% ------------- ------------- 379
      70% ------------- ------------- 377
      90% ------------- ------------- 182
GMA Adv. 200 440 ppm 50% ------------- 223 196
      70% ------------- 212 183
      90% ------------- 135 110
GMA Adv. 200 1300 ppm 50% 95 91 81
      70% 92 88 80
      90% 66 63 56
GMC Adv. 200 200 ppm 70% ------------- ------------- 220
    1300 ppm 70% 66 63 53
GME Adv. 200 200 ppm 70% ------------- ------------- 213
    1300 ppm 70% 63 60 53
GMA Comfo 200 ppm 70% ------------- ------------- 237
    1300 ppm 70% 68 66 60
GMC Comfo 200 ppm 70% ------------- ------------- 220
    1300 ppm 70% 65 63 57
GME Comfo 200 ppm 70% ------------- ------------- 221
    1300 ppm 70% 54 51 42

Caution WARNING

Do not use the data presented in this study as the sole factor in determining the respirator cartridge change-out schedule. An appropriate change-out schedule must be developed by a knowledgeable professional. It should be based on additional factors including the actual workplace conditions, work practices and other conditions which may affect respiratory protection. Failure to determine an appropriate change-out schedule can cause overexposure and result in serious personal injury or death.