MSA Logo

Respirator Test Data

Saturated Aliphatic Hydrocarbons


Hexane

Cartridge Type Concentration Relative Humidity Minutes to 500 ppm
(OSHA PEL)
Minutes to
200 ppm
Minutes to
50 ppm
GMA Adv. 200 200 ppm 50% ------------- ------------- 477
      70% ------------- ------------- 339
      90% ------------- ------------- 197
GMA Adv. 200 600 ppm 50% ------------- 216 199
      70% ------------- 155 142
      90% ------------- 147 136
GMA Adv. 200 1100 ppm 50% 104 98 94
      70% 101 91 86
      90% 84 77 71
GMC Adv. 200 200 ppm 70% ------------- ------------- 242
    1100 ppm 70% 82 75 69
GME Adv. 200 200 ppm 70% ------------- ------------- 219
    1100 ppm 70% 77 72 66
GMA Comfo 200 ppm 70% ------------- ------------- 250
    1100 ppm 70% 78 73 68
GMC Comfo 200 ppm 70% ------------- ------------- 233
    1100 ppm 70% 78 72 68
GME Comfo 200 ppm 70% ------------- ------------- 190
    1100 ppm 70% 74 68 59

The following Alkanes have a service time equal or grater than that of n-Hexane:

Caution WARNING

Do not use the data presented in this study as the sole factor in determining the respirator cartridge change-out schedule. An appropriate change-out schedule must be developed by a knowledgeable professional. It should be based on additional factors including the actual workplace conditions, work practices and other conditions which may affect respiratory protection. Failure to determine an appropriate change-out schedule can cause overexposure and result in serious personal injury or death.


[ Return to Respirator Test Data Index ]